ALPHA 2

,
2 zones fire detection conventional panel Max 32 detectors and/or MCP per line. Alarm/fault output relays, 1 monitored sounders line + 3 output relays and 1 programmable open collector. Alarm prealarm management. Compact panel…

SR2/24

,
2 WAYS RELAY output module, NO-NC 30V/1A to be plugged inside ALPHA 2 panel

ALPHA 4/8/12

, , ,
12 ZONES FIRE DETECTION CONVENTIONAL PANEL equipped with 4 zones (max 12 zones) Max 32 detectors and/or MCP per line. Alarm/fault relays, 1 monitored sounders line, 4 programmable open collectors, 1 programmable input. Alarm prealarm/managment…

ALPHA 4/8/12 FBKEY

, ,
12 ZONES FIRE DETECTION CONVENTIONAL PANEL equipped with 4 zones (max 12 zones) Including integrated fire brigade key process (Action of key disable all function buttons) Max 32 detectors and/or MCP per line. Alarm/fault relays, …

EX4A4

, ,
 ZONES EXPANSION BOARD - max 32 detectors and/or MCP per line 1 or 2 EX4A4 boards can be plugged in ALPHA 4/8/12 and permits to expand the panel to 8 (with 1xEX4A4) or to 12 zones(with 2xEX4A4)

R12P2

, ,
12 WAYS RELAY CARD, NO-NC 30V/1A, to be plugged inside ALPHA 4/8/12 panel, serial communication, permits to repeat states of the panel on 12 relays

REP4MO

, ,
4 SEPARATED MONITORED WAYS SOUNDER CIRCUIT Extension board Permits to have 4 monitored sounder circuits. To be plugged inside the panel alpha 4/8/12 Datasheet rep4mo-eng Datasheet rep4mo-ita  

TR-SDI

, ,
REMOTE INDICATOR PANEL with leds and function keys, to repeat general alarm and fault, local test leds and silence buzzer Datasheet - GBR  

OC05 – Optical smoke detector

,
CONVENTIONAL OPTICAL SMOKE DETECTOR, 1 remote led output, EN54-7 , CE according to CPD/CPR Datasheet - FR Datasheet - NLD Datasheet - GBR Datasheet - ITA

TRC05 – Rate of rise + Fixed heat detector

,
CONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, T° = 62°C, + 9°C/min, 1 remote led output, EN54-5 , CE according to CPD/CPR Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

TSC05-A1S – Fixed heat detector

,
CONVENTIONAL FIXED HEAT DETECTOR, T° = 62°C, 1 remote led output, EN54-5 , CE according to CPD/CPR Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

TSC05-BS – Fixed heat detector

,
CONVENTIONAL FIXED HEAT DETECTOR, T° = 75°C, 1 remote led output, EN54-5 , CE according to CPD/CPR Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

OC05.12 or OC05-.12-AR – Optical smoke detector

,
CONVENTIONAL OPTICAL SMOKE DETECTOR, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version) Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

TRC05.12 or TRC05.12-AR – Rate of rise + fixed heat detector

,
CONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, T° = 62°C, + 9°C/min, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version) Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet…

TSC05-A1S.12 or TSC05-A1S.12-AR – Fixed heat detector

,
CONVENTIONAL FIXED HEAT DETECTOR, T° = 62°C, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version) Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

TSC05-BS.12 or TSC05-BS.12-AR – Fixed heat detector

,
CONVENTIONAL FIXED HEAT DETECTOR, T° = 75°C, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version) Datasheet : fr Datasheet : nld Datasheet : ita Datasheet : gbr

S05SE

,
UNIVERSAL BASE WITH STICK ADDRESS SOCKET for 05-range conventional and addressable detectors Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA  

PES05

,
FLUSHMOUNTING  PIECE FOR BASE (Base not included), permits to flushmount a 05 range detector Datasheet : FR Datasheet : NLD Datasheet :  GBR Datasheet : ITA  

BRI/EM + S05SE – Universal base

,
Universal base with GLANDS HOLE for 05 range, base for tubes connections Datasheet : FR Datasheet : NL Datasheet : GBR Datasheet :  ITA

BRI + S05SE – Universal base waterproof

,
ATERPROOF universal base with glands for 05 range (IP65), base for tubes connections supplied with glands Datasheet : FR Datasheet : GBR Datasheet : NL Datasheet : ITA

GAV – Antivandalism

,
NTIVANDALISM protection grid Datasheet - FR Datasheet - NL Datasheet - GBR Datasheet - ITA  

IRY2+S95 – Infrared flame detector

,
CONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10 class 1 and 2 , CE according to CPD , base included Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA &nbs…

IRY2-IP65 – Infrared flame detector

,
CONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10 class 1 and 2  , CE according to CPD , IP65 box, dim 225x175x80.  

SOUND05 + S05SE – Base with internal sounder

,
BASE WITH INTERNAL SOUNDER 95db @ 1m, Possibility to select 6 tones and 3 intensitivity levels, EN54-3, CE according to CPD Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

DMCL05 – Manual call point

,
CONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass,  led and alarm resistor integrated, RED colour, EN54-11, CE according to CPD Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

DMCL05-J – Manual call point

,
CONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass, led and alarm resistor integrated, YELLOW colour Datasheet : FR Datasheet : NLD Datasheet : ITA Datasheet : GBR

DMCL05-B – Manual call point

,
CONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass, led and alarm resistor integrated, BLUE colour Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

DMC05 E

,
CONVENTIONAL WATERPROOF MANUAL CALL POINT resettable with key without breaking glass,  led and alarm resistor integrated, RED colour, EN54-11, CE according to  CPD/CPR Datasheet : IT Datasheet : GB

BTG05-P5901- Air duct detector housing

,
AIR DUCT DETECTOR HOUSING for 05 range (detector not included), dimensions 220x186x105mm, IP55 Datasheet : ITA Datasheet : GBR    

DAAF-REL – Plug in card

,
PLUG IN CARD with NO contact, permits to repeat the state of alarm (for intrusion panels)

DOF 49

,
DOMESTIC PHOTOELECTRIC SMOKE ALARM DETECTOR With 9V battery,  5 years life duration, 6 years warranty, CE EN14604 according to CPD (Exists also with lithium battery 9Vdc 10 years life duration) Datasheet : GBR Datasheet : ITA &…

HC68 – Linear heat detection

,
LINEAR HEAT DETECTION cable 68°  (price per meter) connectable directly to conventional panels or addressable modules Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA

HC105 – Linear heat detection

,
LINEAR HEAT DETECTION cable 105° (price per meter) connectable directly to conventional panels or addressable modules Datasheet : FR Datasheet : NLD Datasheet : GBR Datasheet : ITA    

ALP24-KIT19

,
FLUSH MOUNTING METALLIC FRAME and backbox for ALPHA 4/8/12 or HEPHAIS 128