ALPHA 4/8/12
Conventional systems, Explosion hazard area products, From 4 up to 12 zones, Panels12 ZONES FIRE DETECTION CONVENTIONAL PANEL equipped with 4 zones (max 12 zones)
Max 32 detectors and/or MCP per line. Alarm/fault relays,
1 monitored sounders line, 4 programmable open collectors,
1 programmable input. Alarm prealarm/managment…
ALPHA 4/8/12 FBKEY
Conventional systems, From 4 up to 12 zones, Panels12 ZONES FIRE DETECTION CONVENTIONAL PANEL equipped with 4 zones (max 12 zones)
Including integrated fire brigade key process (Action of key disable all function buttons)
Max 32 detectors and/or MCP per line. Alarm/fault relays,
…
EX4A4
Conventional systems, From 4 up to 12 zones, Panels ZONES EXPANSION BOARD - max 32 detectors and/or MCP per line
1 or 2 EX4A4 boards can be plugged in ALPHA 4/8/12 and permits to expand the panel to 8 (with 1xEX4A4) or to 12 zones(with 2xEX4A4)
REP4R
Conventional systems, Explosion hazard area products, From 4 up to 12 zones, Panels4 WAYS RELAY CARD
NO-NC 30V/1A , to be plugged inside the panel, connection by wires with programmable open collectors of ALPHA 4/8/12
R12P2
Conventional systems, From 4 up to 12 zones, Panels12 WAYS RELAY CARD,
NO-NC 30V/1A, to be plugged inside ALPHA 4/8/12 panel, serial communication, permits to repeat states of the panel on 12 relays
REP4MO
Conventional systems, From 4 up to 12 zones, Panels4 SEPARATED MONITORED WAYS SOUNDER CIRCUIT
Extension board
Permits to have 4 monitored sounder circuits.
To be plugged inside the panel alpha 4/8/12
Datasheet rep4mo-eng
Datasheet rep4mo-ita
ALFMKXL 32
Conventional systems, PanelsRecessing bezel for ALPHA XL panel
ALTPCA05
Conventional systems, PanelsCommunication card for network, designed to be wired in Fault tolerant (fail safe) loop configuration
ALPOPCARD-8
Conventional systems, Panels8 way output card.
8 voltage free contact relays and 8 open collector Outputs
TR-SDI
Accessories, Conventional systems, PanelsREMOTE INDICATOR PANEL with leds and function keys, to repeat general alarm and fault, local test leds and silence buzzer
Datasheet - GBR
OC05 – Optical smoke detector
Conventional systems, Fire detectorsCONVENTIONAL OPTICAL SMOKE DETECTOR, 1 remote led output, EN54-7 , CE according to CPD/CPR
Datasheet - FR
Datasheet - NLD
Datasheet - GBR
Datasheet - ITA
TRC05 – Rate of rise + Fixed heat detector
Conventional systems, Fire detectorsCONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, T° = 62°C, + 9°C/min, 1 remote led output, EN54-5 , CE according to CPD/CPR
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
TSC05-A1S – Fixed heat detector
Conventional systems, Fire detectorsCONVENTIONAL FIXED HEAT DETECTOR, T° = 62°C, 1 remote led output, EN54-5 , CE according to CPD/CPR
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
TSC05-BS – Fixed heat detector
Conventional systems, Fire detectorsCONVENTIONAL FIXED HEAT DETECTOR, T° = 75°C, 1 remote led output, EN54-5 , CE according to CPD/CPR
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
OC05.12 or OC05-.12-AR – Optical smoke detector
Conventional systems, Fire detectorsCONVENTIONAL OPTICAL SMOKE DETECTOR, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version)
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
TRC05.12 or TRC05.12-AR – Rate of rise + fixed heat detector
Conventional systems, Fire detectorsCONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, T° = 62°C, + 9°C/min, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version)
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet…
TSC05-A1S.12 or TSC05-A1S.12-AR – Fixed heat detector
Conventional systems, Fire detectorsCONVENTIONAL FIXED HEAT DETECTOR, T° = 62°C, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version)
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
TSC05-BS.12 or TSC05-BS.12-AR – Fixed heat detector
Conventional systems, Fire detectorsCONVENTIONAL FIXED HEAT DETECTOR, T° = 75°C, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version)
Datasheet : fr
Datasheet : nld
Datasheet : ita
Datasheet : gbr
S05SE
Conventional systems, Fire detectorsUNIVERSAL BASE WITH STICK ADDRESS SOCKET for 05-range conventional and addressable detectors
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
PES05
Conventional systems, Fire detectorsFLUSHMOUNTING PIECE FOR BASE (Base not included), permits to flushmount a 05 range detector
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
BRI/EM + S05SE – Universal base
Conventional systems, Fire detectorsUniversal base with GLANDS HOLE for 05 range, base for tubes connections
Datasheet : FR
Datasheet : NL
Datasheet : GBR
Datasheet : ITA
BRI + S05SE – Universal base waterproof
Conventional systems, Fire detectorsATERPROOF universal base with glands for 05 range (IP65), base for tubes connections supplied with glands
Datasheet : FR
Datasheet : GBR
Datasheet : NL
Datasheet : ITA
GAV – Antivandalism
Conventional systems, Fire detectorsNTIVANDALISM protection grid
Datasheet - FR
Datasheet - NL
Datasheet - GBR
Datasheet - ITA
IRY2+S95 – Infrared flame detector
Conventional systems, Fire detectorsCONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10 class 1 and 2 , CE according to CPD , base included
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
&nbs…
IRY2-IP65 – Infrared flame detector
Conventional systems, Fire detectorsCONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10 class 1 and 2 , CE according to CPD , IP65 box, dim 225x175x80.
SOUND05 + S05SE – Base with internal sounder
Conventional systems, Fire detectorsBASE WITH INTERNAL SOUNDER 95db @ 1m, Possibility to select 6 tones and 3 intensitivity levels, EN54-3, CE according to CPD
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
DMCL05 – Manual call point
Conventional systems, Manual call pointsCONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass, led and alarm resistor integrated, RED colour, EN54-11, CE according to CPD
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
DMCL05-J – Manual call point
Conventional systems, Manual call pointsCONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass, led and alarm resistor integrated, YELLOW colour
Datasheet : FR
Datasheet : NLD
Datasheet : ITA
Datasheet : GBR
DMCL05-B – Manual call point
Conventional systems, Manual call pointsCONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass, led and alarm resistor integrated, BLUE colour
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
PEDM – Manual call point
Addressable manual call point, Conventional systems, Intelligent / interactive panels and detectors, Manual call pointsPLASTIC FRAME for flush mounting MCP
VPDM – Transparent lift-up
Addressable manual call point, Conventional systems, Intelligent / interactive panels and detectors, Manual call pointsTRANSPARENT LIFT-UP protective cover for MCP, permits a double action (supplied with protection label)
KCTDM – Reset keys
Addressable manual call point, Conventional systems, Intelligent / interactive panels and detectors, Manual call pointsKIT OF 10 RESET KEYS for 05 MCP
DMC05 E
Conventional systems, Manual call pointsCONVENTIONAL WATERPROOF MANUAL CALL POINT
resettable with key without breaking glass, led and alarm resistor integrated, RED colour, EN54-11, CE according to CPD/CPR
Datasheet : IT
Datasheet : GB
BTG05-P5901- Air duct detector housing
Air duct detection, Conventional systemsAIR DUCT DETECTOR HOUSING for 05 range (detector not included), dimensions 220x186x105mm, IP55
Datasheet : ITA
Datasheet : GBR
VESTA – Domestic photoelectric smoke alarm detector
Conventional systems, Stand alone smoke alarm detectorDOMESTIC PHOTOELECTRIC SMOKE ALARM DETECTOR with 9V battery , CE EN14604 according to CPD
Datasheet : GBR
Datasheet : ITA
DAAF-REL – Plug in card
Conventional systems, Stand alone smoke alarm detectorPLUG IN CARD with NO contact, permits to repeat the state of alarm (for intrusion panels)
DOF 49
Conventional systems, Stand alone smoke alarm detectorDOMESTIC PHOTOELECTRIC SMOKE ALARM DETECTOR
With 9V battery, 5 years life duration, 6 years warranty, CE EN14604 according to CPD (Exists also with lithium battery 9Vdc 10 years life duration)
Datasheet : GBR
Datasheet : ITA
&…
HC68 – Linear heat detection
Conventional systems, Linear heat detectionLINEAR HEAT DETECTION cable 68° (price per meter) connectable directly to conventional panels or addressable modules
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
HC105 – Linear heat detection
Conventional systems, Linear heat detectionLINEAR HEAT DETECTION cable 105° (price per meter) connectable directly to conventional panels or addressable modules
Datasheet : FR
Datasheet : NLD
Datasheet : GBR
Datasheet : ITA
DAACO-10
Gas alarm detectorsStand alone Carbon monoxide (CO) gas detector with electochemical sensor, embedded buzzer.Spply with 5 years life duration battery , CE CPD certified.
Datasheet - GBR